Engineers point way to better use of nanotubes as measuring tips

WEST LAFAYETTE, Ind. – Engineers at Purdue University have shown how researchers might better use tiny hollow fibers called "multi-walled carbon nanotubes" to more precisely measure structures and devices for electronics and other applications.

Carbon nanotube
Download image
caption below

Findings will appear in the November issue of the journal Nanotechnology.

Researchers attach the tubes to the ends of imaging instruments called atomic force microscopes. Because the tubes are long and slender, their shape is ideal for the emerging field of "nanometrology," which is precisely measuring structures on the scale of nanometers, or billionths of a meter.

Conventional silicon tips used on the microscopes are shaped like inverted traffic cones. They are fine for measuring relatively flat surfaces, but they do not readily penetrate crevices that often exist in tiny devices and structures, said Arvind Raman, an associate professor of mechanical engineering at Purdue. The silicon tips also wear out quickly, reducing image resolution, whereas the carbon nanotubes have been shown to retain their accuracy after many hours of use, said mechanical engineering doctoral student Mark Strus.

But while nanotubes better penetrate the nooks and crannies of nano-structures, the flexible tubes often stick to the sides of these structures due to attractive forces between individual atoms called van der Waals' forces.

Comparison between a silicon tip (left) and a nanotube
Download image
caption below

"An example I give students is that operating in a nanoscale environment is like having flypaper everywhere because of the attraction of van der Waals' forces," Raman said. "These short-range, inter-atomic forces are very relevant on this size scale because a nanometer is less than 10 atoms wide."

Researchers use nanotubes as probes by inducing a vibration in a portion of the microscope assembly called a microcantilever.

"The microcantilever, which does all of the surface sensing, can be thought of as a very small oscillating diving board on which the silicon tip and nanotube are mounted to the free end," Strus said.

As the microcantilever vibrates, the nanotube tip comes close to the surface but never actually touches the object being imaged. The closer the tip comes to the surface, the more powerful the attractive van der Waals' forces become. The increasing attraction causes changes in the vibration pattern of the oscillating microcantilever, and the changing pattern is carefully monitored to reveal precise changes in contours on the surface of the object, yielding an image.

The same forces that enable the technology to work, however, also cause the sticking action of the probe. The vibrating tip sticks to the sides of the object being imaged, producing "artifacts," or inaccuracies in the measurements and images.

Strus has led research aimed at oscillating the probes in a manner that prevents nanotubes from sticking to structures, and new findings could lead to more accurate measurements using the slender probes. The journal paper was written by Strus, Raman, C-S Han, senior research manager from the Nanomechanical Systems Research Center at the Korea Institute of Machinery and Materials, and C.V. Nguyen, a research scientists from the NASA Ames Research Center in Moffett Field, Calif.

Methods to precisely measure structures on the scale of nanometers will become essential as nanostructures are used more often in applications such as computer chips, advanced sensors, microscopic machines and the creation of new materials. Precision measurements will be critical for developing new standards needed to properly develop, study and manufacture products based on nanotechnology.

Although some researchers are using nanotube tips in place of conventional silicon tips, the technique is still being perfected and has not yet reached widespread commercial use.

"One of our points in this paper is that you can avoid getting these artifacts if you know how to set the parameters," Strus said. "For example, you can change your set point or your amplitude and still get a good image with your nanotube."

The researchers showed precisely how artifacts are created by the sticking nanotubes, which are about 25 nanometers thick. The researchers also have shown how to avoid these artifacts by adjusting operating parameters of the microscope to prevent the tube from sticking.

One way to decrease the sticking is to increase the amplitude, or how far the probe moves each time it vibrates across the surface. With each oscillation, the tube sweeps close to the surface of the object and then swings in the opposite direction, constantly repeating the motion. As the vibrating probe sticks to the sides of a structure, the microscope's computerized controller pulls the tip farther from the surface. Then, after the tip is pulled away, it starts vibrating normally again, and the controller repositions it closer to the surface, again resulting in the sticking action. This cycle repeats, causing the image artifacts.

The researchers demonstrated how to prevent several specific types of artifacts while using nanotubes to take images of tiny tungsten posts about 100 nanometers in diameter and other nano-structures.

The research was funded by the Centre for Nanomechatronics and Manufacturing in South Korea, and the work is associated with Purdue's Birck Nanotechnology Center, which is part of Discovery Park, the university's hub for interdisciplinary research.

Writer: Emil Venere, (765) 494-4709, venere@purdue.edu

Sources: Arvind Raman, (765) 494-5733, raman@ecn.purdue.edu

Mark Strus, (765) 496-6416, mstrus@purdue.edu

Purdue News Service: (765) 494-2096; purduenews@purdue.edu

 

Note to Journalists: A copy of the research paper can be downloaded and is also is available from Emil Venere, (765) 494-4709, venere@purdue.edu.

 

IMAGE CAPTION:
This image shows a carbon nanotube attached to a conventional silicon tip used on an instrument called an atomic force microscope, which is used to measure tiny features on the scale of nanometers. Forces between individual atoms called van der Waals' forces cause the flexible, vibrating probe to stick to the sides of the tiny structures, producing "artifacts," or inaccuracies in the final image. Purdue researchers have shown how to avoid the sticking action and prevent certain artifacts so that nanotubes can be better used in the emerging field of "nanometrology." (Purdue School of Mechanical Engineering)

A publication-quality photo is available at https://www.purdue.edu/uns/uns/images/+2005/raman-nanotubes.jpg

IMAGE CAPTION:
This image shows a comparison between an image taken with a conventional silicon tip (left) and a nanotube, both used on an atomic force microscope to scan the surface of an object to measure tiny contours on the scale of nanometers. While nanotubes are more slender and flexible than the silicon tips, making them ideal to reach into the nooks and crannies of nano-structures, the tubes have a tendency to stick to the sides of the structures because of forces between individual atoms called van der Waals' forces. The sticking action results in "artifacts," or inaccuracies in the final image. The image on the left shows an image taken with a conventional tip, and the other image shows an example of artifacts caused by the sticking action. Purdue researchers have shown how to avoid the sticking action and prevent certain artifacts so that nanotubes can be better used in the emerging field of "nanometrology." (Purdue School of Mechanical Engineering)

A publication-quality photo is available at https://www.purdue.edu/uns/uns/images/+2005/raman-nanotubes2.jpg

 


ABSTRACT

Imaging Artifacts in Atomic Force Microscopy
with Carbon Nanotube Tips

M.C. Strus1, A. Raman, C-S Han2 and C.V. Nguyen3

1 School of Mechanical Engineering, Purdue University,
West Lafayette, IN 47907, USA

2 Centre for Nanomechatronics and Manufacturing, Korean Institute of Machines and Materials, Taejon, Korea

3 NASA Ames Research Center, Moffett Field, CA 94035, USA

Dynamic atomic force microscopy (dynamic AFM) with carbon nanotube tips has been suggested as an enabling tool for high precision nanometrology of critical dimension features of semiconductor surfaces. We investigate the performance of oscillating AFM microcantilevers with multi-walled carbon nanotube (multi-walled CNT) tips interacting with high aspect ratio structures while in the attractive regime of dynamic AFM. We present experimental results on SiO2 gratings and tungsten nanorods, which show two distinct imaging artifacts, namely the formation of divots and large ringing artifacts that are inherent to CNT AFM probe operation. Through meticulous adjustment of operating parameters, the connection of these artifacts to CNT bending, adhesion, and stiction is described qualitatively and explained.


 

To the News Service home page

Newsroom Search Newsroom home Newsroom Archive